Skip to content
Well & TapHome Water Treatment Database

Is there PFAS in Pecan Grove MUD water?

Yes, at low levels. 5 PFAS were detected, all below EPA's 2024 limits.

Pecan Grove MUD Serves 14,913 people · 16 PFOA samples from 4 sampling points · Nov 2024 to Sep 2025 PFAS found, below EPA limits
PFOA Perfluorooctanoic acid not detected
EPA 4
PFOS Perfluorooctanesulfonic acid not detected
EPA 4
PFHxS Perfluorohexanesulfonic acid 0.8 ppt avg · max 3.0
EPA 10
Hazard index GenX, PFBS, PFNA, PFHxS combined 0.1 avg · max 0.3
EPA 1

Also detected, no federal limit: PFPeA, PFBA, PFHxA, PFBS.

Averages are for the worst sampling point, with non-detects counted as zero. Source: EPA UCMR 5.

Pecan Grove MUD is a public water system drawing on surface water, based in Houston, Texas, serving about 14,913 people. Under EPA's Fifth Unregulated Contaminant Monitoring Rule it was tested for 29 PFAS and lithium 16 times across 4 sampling points between Nov 2024 and Sep 2025.

Every PFAS detected

PFAS Detected Highest Worst point avg EPA limit
PFPeA
Perfluoropentanoic acid
16 of 16 92.3 ppt 35.7 ppt none
PFBA
Perfluorobutanoic acid
8 of 16 22.9 ppt 11.8 ppt none
PFHxA
Perfluorohexanoic acid
6 of 16 6.4 ppt 3.5 ppt none
PFBS
Perfluorobutanesulfonic acid
1 of 16 4.5 ppt 1.1 ppt none
PFHxS
Perfluorohexanesulfonic acid
1 of 16 3.0 ppt 0.8 ppt 10 ppt

Not detected: PFHpA, PFUnA, PFDoA, PFDA, PFTrDA, PFOA, PFOS, NMeFOSAA, PFTA, 11Cl-PF3OUdS, PFNA, PFMBA, NEtFOSAA, PFHpS, PFPeS, 8:2 FTS, PFEESA, 9Cl-PF3ONS, PFMPA, 4:2 FTS, 6:2 FTS, HFPO-DA, ADONA, NFDHA.

Lithium, tested in the same program: highest 12.3 ppb, detected in 8 of 16 samples. EPA's health-based screening level is 10 ppb.

What the EPA limits mean here

In April 2024 EPA set enforceable limits of 4 ppt for PFOA and PFOS, 10 ppt each for PFHxS, PFNA and GenX, and a hazard index of 1 for mixtures. Utilities were given until 2029 to comply. In May 2026 EPA proposed keeping only the PFOA and PFOS limits and moving that deadline to 2031. Until that proposal is final, the 2024 limits stand.

Compliance is judged on a running annual average at each entry point, so we show the average at this system's worst sampling point next to its single highest result. UCMR 5 results do not by themselves put a utility in or out of compliance.

What you can do at home

Levels here are under EPA's limits, so no treatment is required. If you want them lower anyway, a certified reverse osmosis system under the sink handles drinking water, and a whole-house carbon filter also takes out the chlorine or chloramine your utility adds.

Other systems in Texas

All 1154 tested systems in Texas

ZIP codes served

77406

As reported by the utility to EPA. Neighbouring ZIPs are often split between systems; your water bill names yours.

Cite this page

Well & Tap. "PFAS in Pecan Grove MUD water: EPA UCMR 5 results." Data: U.S. EPA Fifth Unregulated Contaminant Monitoring Rule, final release August 2026, PWSID TX0790132. https://wellandtap.com/pfas/texas/pecan-grove-mud/

About this data

Source: U.S. EPA, UCMR 5 occurrence data, final release August 2026 (PWSID TX0790132). Population: EPA SDWIS. Averages count results below the reporting level as zero, the same convention EPA uses for running annual averages. Full method.