Is there PFAS in Bloomingdale Utility District water?
Some. At least one sample reached an EPA limit, but the average at every sampling point stayed below it.
Bloomingdale Utility District is a public water system drawing on surface water, based in Kingsport, Tennessee, serving about 13,318 people, including Gate City, Hiltons, Blountville, Kingsport. Under EPA's Fifth Unregulated Contaminant Monitoring Rule it was tested for 29 PFAS and lithium 4 times across 1 sampling point between May 2023 and Feb 2024.
Every PFAS detected
| PFAS | Detected | Highest | Worst point avg | EPA limit |
|---|---|---|---|---|
| PFOS Perfluorooctanesulfonic acid |
1 of 4 | 4.3 ppt | 1.1 ppt | 4 ppt |
Not detected: PFPeS, PFUnA, PFHxA, PFDoA, PFDA, PFHpA, PFHpS, 11Cl-PF3OUdS, PFHxS, PFOA, PFBS, NEtFOSAA, PFMBA, PFEESA, NFDHA, 9Cl-PF3ONS, PFNA, PFTrDA, PFPeA, PFMPA, 8:2 FTS, 4:2 FTS, NMeFOSAA, 6:2 FTS, PFBA, HFPO-DA, ADONA, PFTA.
Lithium, tested in the same program: not detected.
What the EPA limits mean here
In April 2024 EPA set enforceable limits of 4 ppt for PFOA and PFOS, 10 ppt each for PFHxS, PFNA and GenX, and a hazard index of 1 for mixtures. Utilities were given until 2029 to comply. In May 2026 EPA proposed keeping only the PFOA and PFOS limits and moving that deadline to 2031. Until that proposal is final, the 2024 limits stand.
Compliance is judged on a running annual average at each entry point, so we show the average at this system's worst sampling point next to its single highest result. UCMR 5 results do not by themselves put a utility in or out of compliance.
What you can do at home
Two routes work for PFAS. For drinking and cooking water only, a reverse osmosis system certified to NSF/ANSI 58 with a PFOA/PFOS reduction claim is the cheapest proven option. To treat every tap and shower, a whole-house carbon system with enough contact time works, but check that the maker has PFAS test data, not just a marketing claim. See the best filters for PFAS and how PFAS removal works.
Other systems in Tennessee
- Marshall CO Bd P.u. #1 7 PFAS detected
- Paris Bd of Public Utilities none detected
- Sweetwater Utility Board none detected
- Bon Aqua-lyles Utility District none detected
- Rogersville Water System none detected
- Etowah Utilities none detected
All 277 tested systems in Tennessee
ZIP codes served
24251 24258 37617 37660 37664
As reported by the utility to EPA. Neighbouring ZIPs are often split between systems; your water bill names yours.
Cite this page
Well & Tap. "PFAS in Bloomingdale Utility District water: EPA UCMR 5 results." Data: U.S. EPA Fifth Unregulated Contaminant Monitoring Rule, final release August 2026, PWSID TN0000056. https://wellandtap.com/pfas/tennessee/bloomingdale-utility-district/
About this data
Source: U.S. EPA, UCMR 5 occurrence data, final release August 2026 (PWSID TN0000056). Population: EPA SDWIS. Averages count results below the reporting level as zero, the same convention EPA uses for running annual averages. Full method.