Is there PFAS in Lafayette Utilities Water System water?
No PFAS were detected in any of the 10 samples EPA's program collected.
Lafayette Utilities Water System is a public water system drawing on groundwater, based in Lafayette, Louisiana, serving about 169,389 people, including Lafayette, Broussard, Carencro, Church Point, Scott, Youngsville. Under EPA's Fifth Unregulated Contaminant Monitoring Rule it was tested for 29 PFAS and lithium 10 times across 5 sampling points between Nov 2024 and May 2025.
Every PFAS detected
None of the 29 PFAS were found at or above EPA's minimum reporting levels (2 to 20 ppt depending on the compound).
Not detected: PFMPA, PFNA, NFDHA, 11Cl-PF3OUdS, PFMBA, PFPeA, PFEESA, 8:2 FTS, 6:2 FTS, HFPO-DA, ADONA, 9Cl-PF3ONS, PFUnA, PFBS, PFPeS, PFHxS, 4:2 FTS, PFOS, PFHxA, PFOA, PFDA, PFDoA, PFHpA, PFTA, PFTrDA, NEtFOSAA, NMeFOSAA, PFBA, PFHpS.
Lithium, tested in the same program: highest 37.4 ppb, detected in 8 of 10 samples. EPA's health-based screening level is 10 ppb.
What the EPA limits mean here
In April 2024 EPA set enforceable limits of 4 ppt for PFOA and PFOS, 10 ppt each for PFHxS, PFNA and GenX, and a hazard index of 1 for mixtures. Utilities were given until 2029 to comply. In May 2026 EPA proposed keeping only the PFOA and PFOS limits and moving that deadline to 2031. Until that proposal is final, the 2024 limits stand.
Compliance is judged on a running annual average at each entry point, so we show the average at this system's worst sampling point next to its single highest result. UCMR 5 results do not by themselves put a utility in or out of compliance.
What you can do at home
No PFAS action is needed on these results. If your water tastes or smells of chlorine, a whole-house city water filter is the usual fix.
Other systems in Louisiana
- Shreveport Water System 1 PFAS detected
- W Jefferson Ww District 2 1 PFAS detected
- Schriever Water Treatment Service Area 2 PFAS detected
- Lafourche Water District 1 1 PFAS detected
- City of Bossier City Water System none detected
- City of Lake Charles Water System none detected
All 268 tested systems in Louisiana
ZIP codes served
70501 70503 70506 70507 70508 70518 70520 70525 70583 70592 70596
As reported by the utility to EPA. Neighbouring ZIPs are often split between systems; your water bill names yours.
Cite this page
Well & Tap. "PFAS in Lafayette Utilities Water System water: EPA UCMR 5 results." Data: U.S. EPA Fifth Unregulated Contaminant Monitoring Rule, final release August 2026, PWSID LA1055017. https://wellandtap.com/pfas/louisiana/lafayette-utilities-water-system/
About this data
Source: U.S. EPA, UCMR 5 occurrence data, final release August 2026 (PWSID LA1055017). Population: EPA SDWIS. Averages count results below the reporting level as zero, the same convention EPA uses for running annual averages. Full method.