Skip to content
Well & TapHome Water Treatment Database

Is there PFAS in Indiana American Water - Noblesville water?

Yes, at low levels. 1 PFAS was detected, all below EPA's 2024 limits.

Indiana American Water - Noblesville Serves 45,575 people · 6 PFOA samples from 3 sampling points · May 2024 to Nov 2024 PFAS found, below EPA limits
PFOA Perfluorooctanoic acid not detected
EPA 4
PFOS Perfluorooctanesulfonic acid not detected
EPA 4

Also detected, no federal limit: PFPeA.

Averages are for the worst sampling point, with non-detects counted as zero. Source: EPA UCMR 5.

Indiana American Water - Noblesville is a public water system drawing on groundwater, based in Greenwood, Indiana, serving about 45,575 people, including Fishers, Noblesville. Under EPA's Fifth Unregulated Contaminant Monitoring Rule it was tested for 29 PFAS and lithium 6 times across 3 sampling points between May 2024 and Nov 2024.

Every PFAS detected

PFAS Detected Highest Worst point avg EPA limit
PFPeA
Perfluoropentanoic acid
2 of 6 3.3 ppt 3.1 ppt none

Not detected: PFHpS, PFOS, PFBS, PFHpA, PFHxS, PFNA, NMeFOSAA, NEtFOSAA, PFTrDA, PFTA, PFPeS, NFDHA, PFMBA, PFOA, PFMPA, 8:2 FTS, PFUnA, PFDA, PFEESA, PFHxA, 4:2 FTS, 11Cl-PF3OUdS, 9Cl-PF3ONS, ADONA, HFPO-DA, PFBA, 6:2 FTS, PFDoA.

Lithium, tested in the same program: highest 18.2 ppb, detected in 4 of 6 samples. EPA's health-based screening level is 10 ppb.

What the EPA limits mean here

In April 2024 EPA set enforceable limits of 4 ppt for PFOA and PFOS, 10 ppt each for PFHxS, PFNA and GenX, and a hazard index of 1 for mixtures. Utilities were given until 2029 to comply. In May 2026 EPA proposed keeping only the PFOA and PFOS limits and moving that deadline to 2031. Until that proposal is final, the 2024 limits stand.

Compliance is judged on a running annual average at each entry point, so we show the average at this system's worst sampling point next to its single highest result. UCMR 5 results do not by themselves put a utility in or out of compliance.

What you can do at home

Levels here are under EPA's limits, so no treatment is required. If you want them lower anyway, a certified reverse osmosis system under the sink handles drinking water, and a whole-house carbon filter also takes out the chlorine or chloramine your utility adds.

Other systems in Indiana

All 230 tested systems in Indiana

ZIP codes served

46038 46060 46062

As reported by the utility to EPA. Neighbouring ZIPs are often split between systems; your water bill names yours.

Cite this page

Well & Tap. "PFAS in Indiana American Water - Noblesville water: EPA UCMR 5 results." Data: U.S. EPA Fifth Unregulated Contaminant Monitoring Rule, final release August 2026, PWSID IN5229015. https://wellandtap.com/pfas/indiana/indiana-american-water-noblesville/

About this data

Source: U.S. EPA, UCMR 5 occurrence data, final release August 2026 (PWSID IN5229015). Population: EPA SDWIS. Averages count results below the reporting level as zero, the same convention EPA uses for running annual averages. Full method.